Rheem Value Series
Heat Pumps
FORM NO. P11-803 REV. 1
14PJM- Series
Efficiencies up to 14.50 SEER/12.00 EER/8.50 HSPF
Nominal Sizes 1.5-5 Ton [5.28 to 17.6 kW]
Rheem Value Series remote heat pumps offer comfort and
depend ability for single, multi-family and light commercial
applications.
Painted louvered steel cabinet
Easily accessible control box
Condenser coils constructed with copper tubing and
enhanced aluminum fins
Grille/Motor mount for quiet fan operation
Filter Drier (shipped – not installed)
Air
Heat Pumps
14PJM Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit
www.energystar.gov.”
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Heat Pumps

Rheem Value SeriesHeat PumpsFORM NO. P11-803 REV. 114PJM- SeriesEfficiencies up to 14.50 SEER/12.00 EER/8.50 HSPFNominal Sizes 1.5-5 Ton [5.28 to 17.6

Strona 2 - TABLE OF CONTENTS

AirPerformance Data14PJM Series10Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 3 - Accessories

AirPerformance Data14PJM Series11Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 4

AirPerformance Data14PJM Series12Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 5

AirPerformance Data14PJM Series13Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 6

14AirPerformance Data14PJM SeriesModel NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 7

15AirPerformance Data14PJM SeriesModel NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 8

16AirPerformance Data14PJM SeriesModel NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB

Strona 9

AirElectrical and Physical Data14PJM Series17ModelNumber14PJMELECTRICAL PHYSICALPhaseFrequency (Hz)Voltage (Volts)CompressorFan MotorFull LoadAmperes(

Strona 10

AirUnit Dimensions14PJM Series18Unit DimensionsModel No.14PJMUnit Dimensions30 315/8 [803.2] 315/8 [803.2]Width “W”Inches [mm]Length “L”Inches [mm]Hei

Strona 11

AirRefrigerant Line Size Information14PJM Series19Suction Line Length/Size versus Capacity Multiplier (R-410A)Suction Line Run—Feet [m]OptionalStandar

Strona 12

AirTable of Contents14PJM Series2TABLE OF CONTENTSModel Number Identification ...

Strona 13

AirLimited Warranty14PJM Series20GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal

Strona 14

AirNotes14PJM Series21

Strona 15

AirNotes 14PJM Series22

Strona 16

AirNotes 14PJM Series23

Strona 17 - Electrical and Physical Data

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Strona 18 - Unit Dimensions

AirModel I.D./Accessories/Compressor14PJM Series3Model Number Identification14 P J 18 NOMINAL COOLING CAPACITY18 = 18,000 BTU/HR [5.28 kW]24 = 24

Strona 19 - 14PJM Series

AirPerformance Data14PJM Series4Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Strona 20

AirPerformance Data14PJM Series5Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Strona 21

AirPerformance Data14PJM Series6Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Strona 22

AirPerformance Data14PJM Series7Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Strona 23

AirPerformance Data14PJM Series8Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Strona 24 - The new degree of comfort

AirPerformance Data14PJM Series9Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I