Power Vent / Intellivent with FVIR ClassroomContents:● GTC 070 r3 Intellivent Service Handbook● Technical Bulletin Intellivent with FVIR● Technical Bu

Strona 2

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 20057 of 24Wiring Harness Connection DiagramModels Equipped

Strona 3

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 20058 of 24INTELLI-VENT™ SEQUENCE OF OPER

Strona 4 - INTELLI-VENT™ FEATURES

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 20059 of 24INTELLI-VENT™ TROUBLESHOOTING GUIDE Error Codes &

Strona 5 - INTELLI-VENT™ CONSTRUCTION

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200510 of 24ERROR CODE 2 - REVERSED POLAR

Strona 6 - INTELLI-VENT™ OPERATION

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200511 of 24ERROR CODE 4 - PRESSURE SWITCH CIRCUIT REMAINS O

Strona 7 - TEMPERATURE SETTINGS

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200512 of 24ERROR CODE 5 - IGNITOR FAILUR

Strona 8 - GAS PRESSURE REQUIREMENTS

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200513 of 24ERROR CODES - 7, 8, 9 - INTERNAL CONTROL FAILURE

Strona 9 - (between pin 3 and 4)

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200514 of 24ERROR CODE 11 - HIGH TEMPERAT

Strona 10

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200515 of 24ERROR CODE 14 - RESISTOR WIRE OPEN OR SHORTED Th

Strona 11

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200516 of 24TECHNICAL BULLETIN - IGNITION

Strona 13 - 10 of 24

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200517 of 24FLAME SENSOR ALIGNMENT (CONT)

Strona 14 - 11 of 24

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200518 of 24BURNER CHECK LISTREMOVE BURNE

Strona 15 - 12 of 24

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200519 of 24FLUE BAFFLE & FLUE RESTRICTOR CHECKIf the fl

Strona 16 - 13 of 24

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200520 of 24TECHNICAL BULLETIN - AIR PRES

Strona 17 - 14 of 24

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200521 of 24AIR PRESSURE SWITCH CONSTRUCTIONThe switch below

Strona 18 - 15 of 24

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200522 of 24AIR PRESSURE SWITCHES - DIFFE

Strona 19 - FLAME SENSOR ALIGNMENT

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 200523 of 24AIR PRESSURE SWITCH TESTINGTo test the performan

Strona 20 - FLAME SENSOR ALIGNMENT (CONT)

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 200524 of 24AIR PRESSURE SWITCH CIRCUITS1

Strona 21 - BURNER CHECK LIST

Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models This bulletin will simplify vent terminat

Strona 22

Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models This bulletin will simplify vent termination

Strona 23 - 20 of 24

INTELLI-VENT™ CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA – 0605

Strona 24 - AIR PRESSURE SWITCH OPERATION

Additional copies are available from the Ashland City Advertising Department Prepared by the A. O. Smith/State

Strona 25 - Normal State Activated State

TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHARTA. O. Smith Water Products Company AHSTB02807 Technical Training DepartmentAshland C

Strona 26 - AIR PRESSURE SWITCH TESTING

A. O. Smith Water Products Company AHSTB02807 Technical Training DepartmentAshland City, Tennessee © 2006 2 of 5 Intelli-Vent Trouble Chart FVIR AOS.f

Strona 27 - AIR PRESSURE SWITCH CIRCUITS

TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHARTA. O. Smith Water Products Company AHSTB02807 Technical Training DepartmentAshland C

Strona 28

A. O. Smith Water Products Company AHSTB02807 Technical Training DepartmentAshland City, Tennessee © 2006 4 of 5 Intelli-Vent Trouble Chart FVIR AOS.f

Strona 29

TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHARTA. O. Smith Water Products Company AHSTB02807 Technical Training DepartmentAshland C

Strona 31

Tuesday, January 16, 2007Air Pressure SwitchesThis bulletin has been prepared to explain and illustrate the construction, operation, and testing proce

Strona 32

Air Pressure Switch ConstructionAir Pressure Switch OperationAir pressure switches activate in response to pressure sensed through a tube. One end of

Strona 33 - # LED STATUS PROBLEM SOLUTION

Air Pressure Switch Operation (cont)Contact Actions:The “action” of the contacts refers to what causes the switch to activate, to change from it’s “no

Strona 34

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 20051 of 24INTELLI-VENT™ FEATURESThe Intelli-Vent™ is a comb

Strona 35

Testing the performance of air pressure switches involves three procedures.First Procedure is a normal state test to determine if the switch contacts

Strona 36

Third Procedure is a pressure test and requires a digital manometer capable of reading positive and negative pressures. A good range of operation woul

Strona 37 - Technical Bulletin TB-A023-06

Third Procedure - Normally Open Switches (cont):Pressure reading taken DOES NOT reach the activation pressure (cont):Ensure the sensing tube is connec

Strona 38 - Air Pressure Switch Operation

Air Pressure Switch TypesNormally Open = NONormally Closed = NCContact States Contact ActionsClose on a rise in pressureClose on a fall in pressureOpe

Strona 39 - Tools Required for Testing

Air Pressure Switch CircuitResidential Power-Vent & Power-Direct-Vent Water HeatersAir Pressure Switch CircuitCyclone Water Heater14Blocked Exhaus

Strona 40 - Air Pressure Switch Testing

Intelli-Vent™ Sequence of Operation

Strona 44 - (BTH 120, 250, 300, 400 only)

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 20052 of 24INTELLI-VENT™ CONSTRUCTIONMani

Strona 45

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 20053 of 24INTELLI-VENT™ OPERATIONPRE START UP CHECK LIST• C

Strona 46

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 20054 of 24TEMPERATURE SETTINGSResidentia

Strona 47

INTELLI-VENT TROUBLESHOOTING GUIDETechnical Training Department Ashland City, Tennessee © 20055 of 24INTELLI-VENT™ SPECIFICATIONSGAS PRESSURE REQUIREM

Strona 48

INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 20056 of 24INTELLI-VENT™ WIRING CONNECTIO

Komentarze do niniejszej Instrukcji

Brak uwag