Rheem RXIH-AS09A Przewodnik Instalacji Strona 19

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 18
Humidification System
17 69-2307—01
Slide the cover back into place and secure captive screw.
Turn on the water supply and plug in the humidifier.
13
The Press Reset light will blink when
power is applied.
Press/releasetheRESETbuttonto
ready the humidifier. If not pushed,
the humidifier will automatically move
to ready after five minutes.
14
POWER
HUMIDIFYING
CLEAN TANK
CALL SERVICE
PRESS RESET
PRESS EMPTY
RESET
EMPTY
SEE LABEL BELOW
!
M24763
M24762
Confirm that the furnace blower turns on to circulate air. This will take about 1015
minutes upon call for humidity.
16
Important for Remote Installation:
After the humidifier has produced steam for 10–15 minutes, check the integrity of the
remote hose to ensure no sags have occurred. Add or adjust clamps if necessary to
ensure 2 in. per foot continuous slope.
Turn the control to a high setpoint (60% +). Be sure to turn this back down when test-
ing is complete. “Off” will turn the humidifier off.
15
WIRIng WIRIng
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 27 28

Komentarze do niniejszej Instrukcji

Brak uwag